| Mounting Frame for two collectors (vertical installation) |
Mounting Frame for one collector (vertical installation) |
 |
 |
| Mounting frame for two SOL 25 Plus collectors. For vertical installations. In combination with the BP, BW, BF S and BF W mounting hardware sets, permits installation on wood / shingled roofs, metal roofs, flat roofs or walls. Can also be used to mount one collector, horizontal. |
Mounting frame for one SOL 25 Plus Collector. For vertical installations. In combination with the BP, BW, BF S and BF W mounting hardware sets, permits installtion on wood / shingled roofs, metal roofs, flat roofs or walls. |
|
|
| 45° Mounting hardware (horizontal orientation) |
45° Mounting hardware (vertical orientation) |
 |
|
For horizontal installation on a flat roof or wall. Two needed per frame.
Contains:
• 1 support, vertical
• 1 support, horizontal
• 1 support, transverse
• 1 brace
• 1 set each M 10 & M 6 nuts and bolts |
For vertical installation on a flat roof or wall. Two needed per frame.
Contains:
• 1 support, vertical
• 1 support, horizontal
• 1 support, transverse
• 1 brace
• 1 set each M 10 & M 6 nuts and bolts |
| |
| Frame tilt system |
Flush mount kit |
|
|
Frame tilt system for adjusting tilt on roofs 10 to 30 degrees. Two needed per frame.
Contains:
• Adjustabe riser strur set
• 4 L brackets
• 1 Brace
• 1 Collector rail
• 5 sets M 10 nuts and bolts
• 5 sets M 6 x 2 nuts and bolts
| One needed per frame.
Contains:
• 4 L brackets
• 2 collector rails
• 8 sets M 10 nuts and bolts |
| |
| Frame connector kit
| Flexible stainless steel insulated tube |
 |
 |
Frame connector kit to join multiple roof mounting frames for a row of collectors.
Contains:
• 2 Frame connectors
• 8, M 10 nuts and bolts
| This flexible connection tube will provide the plumbing connection between two collectors. |
| |
| Solar pump station
| Goldline controller |
 |
|
• Panel mounted
• Goldline controller
• 2 10K sensors
• Circulator
• 2 Boiler drains
• 1 Check valve
|
• 1 Expansion tank
• 1 Pressure releif valve
• 1 Flowmeter
• 1 Return thermometer
• 1 Temp / pressure guage
• 1 Air vent |
|
• Goldline differential controller
• Line cord outlet for circulator |
| |
| 10K Strap on sensor
| 10K Immersion sensor |

|  |
| 10K Strap / bolt on sensor for Goldline controller |
10K Immersion well type sensor for Goldline controller |
| |
| Glycol - 20 liters / 5.28 gallons |
Sensor well |
 |
 |
| Ready to use mixture
| Well for sensor, used in conjuction with solar differential controller |